InnovaChem Systems LLP Shop NoN

INNOVA · CIP, dairy & food processing

INNOVA CIP AlkaliPlus: alkaline CIP booster for heavy fat and protein soil

INNOVA CIP AlkaliPlus is an alkaline cip booster made by InnovaChem Systems LLP in Greater Noida, India. Dosed into the caustic circuit to boost fat and protein soil removal, for high-load routes and heavy CIP duty, without added corrosivity. Packs: 5 kg and 30 kg packs. Dose, temperature and contact time are on the TDS, sent on request.

What are the INNOVA CIP AlkaliPlus specifications?

ProductINNOVA CIP AlkaliPlus
TypeAlkaline CIP booster
CategoryCIP, dairy & food processing
Pack sizes5 / 30 kg
Dose, temperature, contact timeOn the TDS, sent on request
DocumentsSDS and TDS on request · CoA with every batch
Made byInnovaChem Systems LLP, Greater Noida West, India
CertificationsISO 9001:2015 · GMP (IAF)

What makes INNOVA CIP AlkaliPlus different?

  • Boosts soil break in caustic wash
  • Targets fat and protein residue
  • Works with existing lye dosing

Where can you use INNOVA CIP AlkaliPlus?

  • CIP and COP: Milk silos, pasteurisers, heat exchangers, pipelines. Alkaline and acid in sequence, then sanitiser.
  • Alkaline boost dosed into the caustic circuit for high-load routes.
  • Alkaline booster for fat and protein.

Where not to use: check the TDS before use on aluminium, galvanised steel, soft metals or coated surfaces. Never mix with other chemicals.

How do you use INNOVA CIP AlkaliPlus?

  1. Pre-rinse with water to push out product and loose soil.
  2. Dose INNOVA CIP AlkaliPlus into the caustic circuit at the dose and temperature on the TDS.
  3. Rinse with water.
  4. On acid-wash days, circulate INNOVA CIP Descale, then rinse.
  5. Sanitise with INNOVA PAA 15 before production starts (no rinse).

What dose, temperature and contact time are typical?

These are typical ranges from published guidance for this type of product, to help you plan. The INNOVA CIP AlkaliPlus TDS gives its exact dose, temperature and contact time; where they differ, follow the TDS.

Typical alkaline CIP ranges
WhatTypical range
Strength, milking systems and cold lines0.5 to 1% caustic in hot water (about 1% in cold water) [source]
Strength, pasteurisers and other hot surfaces1 to 2% as NaOH [source]
Temperature75 to 80 °C at the start of a farm hot wash; 77 to 82 °C on pasteurisers [source]
Circulation time8 to 10 minutes on milking systems; 45 to 60 minutes on pasteurisers [source]
FlowAt least 1.5 m/s through the largest line [source]

What does INNOVA CIP AlkaliPlus pair with?

Which problems does INNOVA CIP AlkaliPlus solve?

Which documents come with INNOVA CIP AlkaliPlus?

What mistakes should you avoid with INNOVA CIP AlkaliPlus?

  • Skipping the pre-rinse, so the detergent is spent on loose milk instead of the film.
  • Letting the wash cool down mid-cycle, so fat re-deposits on the surface.
  • Cutting circulation short on hot surfaces such as pasteuriser plates.
  • Running the acid step before the alkaline step, which can set protein onto steel.
  • Leaving caustic in the line before the sanitiser.

How do you check the clean worked?

  • The final rinse water reads neutral on pH paper.
  • No greasy film or white bloom on tank walls, spray balls and outlet valves.
  • An ATP swab of the outlet valve and spray ball passes your limit.
  • A titration or conductivity check shows the wash was at strength.

How should you store and handle INNOVA CIP AlkaliPlus?

  • Caustic cleaners are corrosive: wear chemical gloves, goggles and an apron when handling the concentrate.
  • Always add the product to water, never water to the product, to avoid splashing and heat.
  • Store away from acids and chlorine products, in the closed original container, upright and off the floor.
  • Read the SDS before first use and keep it where the product is used.

What should you tell us for a quote on INNOVA CIP AlkaliPlus?

  • The equipment or surface you clean, and the soil (fat, protein, scale, oil)
  • Your water hardness, if known, and the wash temperature you can reach
  • Pack size and monthly volume
  • Your city, and whether you want a sample or a site trial first

We reply within one working day with a price, the SDS and TDS, and a suggested dose to validate on site.

INNOVA CIP AlkaliPlus: quick answers

What is INNOVA CIP AlkaliPlus used for?

INNOVA CIP AlkaliPlus is an alkaline cip booster. Dosed into the caustic circuit to boost fat and protein soil removal, for high-load routes and heavy CIP duty, without added corrosivity.

What pack sizes is INNOVA CIP AlkaliPlus available in?

INNOVA CIP AlkaliPlus is supplied in 5 kg and 30 kg packs. Tell us your monthly volume and we suggest the right pack.

Where is INNOVA CIP AlkaliPlus used?

CIP and COP: Milk silos, pasteurisers, heat exchangers, pipelines. Alkaline and acid in sequence, then sanitiser. Alkaline boost dosed into the caustic circuit for high-load routes. Alkaline booster for fat and protein.

What dose and temperature should I use for INNOVA CIP AlkaliPlus?

Use the dose, temperature and contact time on the INNOVA CIP AlkaliPlus technical data sheet. They depend on your soil, water hardness and equipment, so we confirm them after a site visit or trial.

What strength and temperature does alkaline CIP usually need?

Published dairy guidance uses 0.5 to 1% caustic at 75 to 80 °C for 8 to 10 minutes on milking systems, and 1 to 2% NaOH at 77 to 82 °C for 45 to 60 minutes on pasteurisers. Use the INNOVA CIP AlkaliPlus TDS for its exact dose.

How do I get the SDS, TDS and price for INNOVA CIP AlkaliPlus?

Ask the InnovaChem team through the quote form, on +91 78277 29936 or at contact@innovachem.in. We share the SDS and TDS on request, quote by pack size and volume, and send a certificate of analysis with every batch.

Talk to us about INNOVA CIP AlkaliPlus

Tell us the application, pack size and monthly volume. We reply within one working day.

Reviewed by the InnovaChem technical team · Updated

CallWhatsAppRequest a quote