InnovaChem Systems LLP Shop NoN

Food plants · Changeovers

Allergen changeover cleaning in food plants

An allergen changeover clean removes every trace of the last product before the next one starts. Dry-clean loose material, foam or wash with a degreaser such as INNOVA DegreasePro or INNOVA Chlorfoam, scrub hard-to-reach parts, rinse, check visually and with a test where possible, then sanitise. Codex CXC 80-2020 sets out the principles.

Goal
No carry-over to the next batch
Clean with
DegreasePro · Chlorfoam · Teepol HD
Verify
Visual check plus test
Reference
Codex CXC 80-2020

Why changeovers fail

Most carry-over comes from places that are hard to see: under conveyor belts, inside hoppers, in seals and in the dust on overhead structures. Codex asks food businesses to manage allergens with validated cleaning, scheduling and verification [1].

Changeover cleaning sequence
StepWhat to doINNOVA product
1. Dry cleanRemove loose product, crumbs and powder by scraping and vacuumingColour-Coded Cleaning Tools
2. Wash or foamApply detergent or foam to break down fat, starch and proteinINNOVA DegreasePro, INNOVA Chlorfoam or INNOVA Teepol HD
3. ScrubScrub seals, corners and hard-to-reach partsColour-Coded Cleaning Tools
4. RinseRinse with low-pressure waterWater
5. VerifyVisual inspection; allergen or protein test where availableNone
6. SanitiseSanitise food contact surfacesINNOVA QuatShield or INNOVA PAA 15

Good practice

  • Schedule allergen-containing products last, then do the full clean.
  • Use dedicated, colour-coded tools for allergen areas.
  • Avoid high-pressure water that spreads residue onto clean areas.
  • Record each changeover clean and its verification result.

Download: Allergen changeover cleaning checklist (PDF) InnovaChem checklist IC-CL-08. Free, no email needed.

Products and machines used

Quick answers

How do you clean for an allergen changeover?

Dry-clean loose material, wash or foam with a suitable degreaser, scrub hidden parts, rinse, verify visually and with a test where available, then sanitise. Record every changeover clean.

Can a sanitiser remove allergens?

No. Sanitisers kill microbes but do not remove allergen protein. Allergen changeover needs a full clean that physically removes residue, then a check such as a visual inspection or an allergen swab, before the sanitiser.

Who sets the rules for allergen management?

The Codex code of practice on food allergen management (CXC 80-2020) sets the general approach, and FSSAI Schedule 4 expects a documented cleaning programme that covers changeovers.

Sources

  1. Codex Alimentarius CXC 80-2020: Code of practice on food allergen management for food business operators
  2. Codex Alimentarius CXC 1-1969 (rev. 2020): General principles of food hygiene

Want this checked at your plant?

Take the free hygiene check, or ask for a site visit and trial with your team.

Sanitiser strengths at a glance

Typical no-rinse limits for food-contact surfaces. Your product TDS and your validated programme govern.
WhatTypical range
Peracetic acid (INNOVA PAA 15)100 to 200 ppm; no-rinse limit 200 ppm [source]
Chlorine (INNOVA Hypo)50 to 200 ppm available chlorine; no-rinse limit 200 ppm [source]
Quat (INNOVA QuatShield)150 to 400 ppm; most no-rinse limits 200 ppm [source]
Alkaline CIP (INNOVA CIP 50)0.5 to 2% at 75 to 82 °C [source]
Acid CIP (INNOVA CIP Descale)0.5 to 1.5% at 55 to 70 °C, 10 to 20 minutes [source]

How often should each clean happen?

A simple schedule for a documented cleaning programme, as FSSAI Schedule 4 expects. Adjust it to your plant, products and audit findings.

WhenWhat to do
Every shiftClean food-contact surfaces and equipment after production; sanitise before the next start; clean floors and drains at the end of the shift; log each clean.
Every dayRun CIP on lines, tanks and fillers after use; check sanitiser strength with test strips; empty and wash bins.
Every weekRun the acid wash your programme sets; deep clean walls, overheads and non-contact frames; review the cleaning records.
Every monthTrend ATP or swab results and fix repeat failures; refresh staff training; check that each chemical’s SDS and TDS on file are current.

What do hygiene auditors look for?

  • A written cleaning SOP for each area and piece of equipment, with the chemical, method and frequency.
  • Signed cleaning records for every shift, with any failed check and the corrective action.
  • A current SDS and TDS on file for every cleaning chemical in use.
  • Logged sanitiser strength checks, such as test-strip readings in ppm.
  • Colour-coded tools kept in their zones, and chemicals stored away from food.
  • Verification results, such as ATP or swab trends, and training records for the cleaning team.

Related reading