Beverage lines leave sugar, pulp, colour and biofilm in pipes, tanks and fillers. Clean them with a chlorinated alkaline CIP detergent such as INNOVA CIP TC86, add an acid step for scale, control foam with INNOVA AntiFoam SIL900 on foam-prone lines, and sanitise with INNOVA PAA 15 or INNOVA HP35.

CIP
INNOVA CIP TC86
Foam control
INNOVA AntiFoam SIL900
Sanitise
INNOVA PAA 15 · HP35
Fillers
Oxidiser sanitising

Typical beverage CIP

Beverage CIP sequence
StepPurposeINNOVA product
Pre-rinseRemove productWater
Alkaline washRemove sugar, pulp, colour and biofilmINNOVA CIP TC86
RinseRemove detergentWater
Acid washRemove scaleINNOVA CIP Descale
SanitiseOxidising, no-rinseINNOVA PAA 15 or INNOVA HP35
Foam controlWhere foaming slows CIPINNOVA AntiFoam SIL900

Fillers need extra care

Fillers have valves, nozzles and seals where product sits. Aseptic fillers need oxidiser sanitising and no chlorinated residue, which is why INNOVA HP35 is used there.

Products used

Quick answers

When should I use a chlorinated CIP detergent?

Where protein, colour or biofilm needs extra cleaning power, such as juice and flavoured milk lines. Do not use chlorinated products where aseptic fillers require chlorine-free sanitising.

Why does beverage line CIP need an acid step?

Hard water and some products leave mineral scale in fillers, heat exchangers and pipes. A typical acid CIP runs 0.5 to 1.5% at 55 to 70 °C for 10 to 20 minutes after the alkaline wash, then a rinse to neutral.

Which sanitiser suits filler heads?

Peracetic acid is widely used on fillers because it works cold and leaves no taint. US FDA rules allow up to 200 ppm on food-contact surfaces without a rinse.

Sources

  1. Tetra Pak Dairy Processing Handbook: Cleaning of dairy equipment
  2. USDA AMS: Peracetic acid technical report (handling and processing)

Want this checked at your plant?

Take the free hygiene check, or ask for a site visit and trial with your team.

Sanitiser strengths at a glance

Typical no-rinse limits for food-contact surfaces. Your product TDS and your validated programme govern.
WhatTypical range
Peracetic acid (INNOVA PAA 15)100 to 200 ppm; no-rinse limit 200 ppm [source]
Chlorine (INNOVA Hypo)50 to 200 ppm available chlorine; no-rinse limit 200 ppm [source]
Quat (INNOVA QuatShield)150 to 400 ppm; most no-rinse limits 200 ppm [source]
Alkaline CIP (INNOVA CIP 50)0.5 to 2% at 75 to 82 °C [source]
Acid CIP (INNOVA CIP Descale)0.5 to 1.5% at 55 to 70 °C, 10 to 20 minutes [source]

How often should each clean happen?

A simple schedule for a documented cleaning programme, as FSSAI Schedule 4 expects. Adjust it to your plant, products and audit findings.

WhenWhat to do
Every shiftClean food-contact surfaces and equipment after production; sanitise before the next start; clean floors and drains at the end of the shift; log each clean.
Every dayRun CIP on lines, tanks and fillers after use; check sanitiser strength with test strips; empty and wash bins.
Every weekRun the acid wash your programme sets; deep clean walls, overheads and non-contact frames; review the cleaning records.
Every monthTrend ATP or swab results and fix repeat failures; refresh staff training; check that each chemical’s SDS and TDS on file are current.

What do hygiene auditors look for?

  • A written cleaning SOP for each area and piece of equipment, with the chemical, method and frequency.
  • Signed cleaning records for every shift, with any failed check and the corrective action.
  • A current SDS and TDS on file for every cleaning chemical in use.
  • Logged sanitiser strength checks, such as test-strip readings in ppm.
  • Colour-coded tools kept in their zones, and chemicals stored away from food.
  • Verification results, such as ATP or swab trends, and training records for the cleaning team.